ENDEAVOR® 5-10KVA

ON-LINE UNINTERRUPTIBLE POWER SUPPLY

ENDEAVOR® 5-10KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY

Double conversion rack/tower UPSs with LCD Display for critical IT, telecommunications, and security systems

The Minuteman® Endeavor™ 5-10kVA Series UPS combines transient free pure sine wave output, extended runtime, generator compatibility, and redundant or parallel configurations for critical applications. A front-panel LCD display provides visual notification of the UPS status, including AC input status, battery status, and UPS fault indication.

APPLICATIONS

  • High-Density Installations
  • Enterprise Network Installations
  • Network Corporate Servers
  • Telecom/VoIP Systems
  • Extended Runtime

Download Product Brochure | Download Product User Manual

Mission critical applications demand the best power quality – Endeavor 5-10kVA systems deliver it in versatile, easily configurable packages that can be tailored to your specific needs.

Endeavor 5-10kVA Upgraded Features

  • User-friendly LCD Display:
    Minuteman’s familiar LCD interface provides real-time status and control of the unit
  • Easy order model numbers:
    No more individual modules for ordering
  • Expands the Endeavor product family:
    Models up to 10kVA in a rack/tower format allows paralleled systems up to 20kVA in capacity
  • Output receptacle configurations on some models:
    All dual-voltage output models will have standard receptacle configurations
  • All 5/6kVA models include an L6-30P/pigtail power cord

Parallel Installations Made Easy

  • Configure 2 ED 5-10kVA units in parallel for capacity or redundancy
  • System automatically switches between parallel for redundancy (N+1) and capacity based on attached load
  • Parallel installs – more user-friendly than ever before

LCD Status Panel


The Endeavor 5-10kVA front panel display provides a range of information to users, including:

    1.  Unit status indicators
    2.  Load & battery meters
    3.  Power status, runtime
    4.  Scroll, mute, & power controls
    5.  Error codes/faults

The LCD panel is designed so that it can be oriented vertically or horizontally depending on the installation orientation of the UPS.

Electrical Characteristics

Digital Signal Processor

  • Reduced number of components in the UPS also reduces the potential for defects or malfunctions
  • Digital Signal Processor, (DSP), combines many components into a single processor, increasing the reliability of the UPS and reducing any downtime potential
  • Helps ensure stable, quality power and long life span

High Output Power Factor

  • All models feature an output power factor of 0.9 which increases the Watt capacity of the units
  • Larger capacities in a smaller UPS VA rating can reduce the overall cost of the UPS solution for a specific load requirement

Output T.H.D.

  • Endeavor units maintain an output AC signal within 2% of a true sine wave pattern (Total Harmonic Distortion)
  • Prevents equipment damage from internal heat build up on sensitive connected equipment

Overload Capacity

  • Sudden spikes can occur when supporting IT infrastructure, industrial equipment, security installations or any electrically-driven load
  • Endeavor UPSs are designed to support such situations with the ability to absorb up to 150% of its rated load for up to 30 seconds
  • Allows the UPS to be sized for maximum capacity without worry of overload and shutdown, providing cost-savings

Independent Battery Bypass

  • An independent battery circuit allows the Endeavor UPS to operate in Normal Mode, even with weak, dead, or defective batteries
  • Endeavor UPSs monitor internal battery status at regular intervals; If the UPS detects weak or bad batteries, it will engage an audio alarm and also any preconfigured electronic notifications
  • Normal AC output will be maintained as long as utility power is supplied within the UPS’ nominal input range
  • The UPS will have a constant 120/208/240V signal and protection from any dangerous spikes or surges while allowing time to replace batteries without having to shut down connected equipment

Optional 240V Output

  • Endeavor units can be configured from the factory for use with 240V input and output applications for an additional charge
  • Include ED-240VAC with Endeavor 5-10 order for 240V configuration
  • For more information about this option, please contact your Minuteman representative

Communication Features

Bundled with SentryHD software

  • Minuteman SentryHD auto-shutdown and monitoring software included

SNMP-compatible (with SNMP-NET and SNMP-NV6 cards)

  • All models include a standard internal communication slot which is compatible with all current Minuteman SNMP card options
  • Adding an SNMP-NET or SNMP-NV6 card allows remote management and control over any IP-based network
  • The Option card slot and serial communications port can be operated simultaneously, allowing SNMP to be used in conjunction with Minuteman SentryHD software
  • SNMP enables SmartECO mode for increased energy savings

Other Features

Minuteman Reliability for Large Applications

  • RoHS 2 Compliant:
    as defined by the EU for the reduction of hazardous substances in electrical equipment: 2011/65/EU
  • 3-yr Standard Warranty
    covering all parts and labor, as well as non-pro-rated coverage of batteries
  • 5-year Extended Warranty Plans available
  • Platinum Protection Plan
    Insures properly connected equipment up to $200,000 (Continental U.S. and Canada only)

 

Key features include:

  • True double-conversion online technology:
    Maximum protection for critical equipment
  • Digital Signal Processor Design
    Higher reliability through reduced number of components used in the UPS
  • Higher power factors (0.9pf)
    Increases the real power capacity of each individual model
  • 120VAC/208VAC models with standard receptacles
    Provides flexibility for support of multiple voltages used on connected loads
  • Real-time LCD status display
    See power and unit status, estimated runtime, and more in real time
  • Parallelable to 20kVA
    Scalable capacity to grow with the customer’s loads
  • 240V input/output configuration optional
    Units can be configured for 240V power for an additional charge
  • Automatic Internal Bypass
    The UPS will sound an alarm and go to bypass mode when an internal fault, (either hardware or battery), is detected
  • Independent Battery Bypass
    The unit can operate as a voltage regulator, even with dead or defective batteries
  • Smart Fan Control
    Variable speed fan control maximizes the cooling of the UPS while maintaining optimum efficiency
  • Cold Start Function
    Start UPS even without utility power
  • Simultaneous Communication Options
    Greater flexibility in the management and monitoring of the UPS system

Battery Technology

Extended Runtime Capability

  • All models come bundled with a battery pack module
  • For protection through extended blackouts, the Endeavor Series can also utilize connections built into each battery pack to connect multiple units, providing virtually unlimited runtime capabilities
  • See the accessories tab for more information

External Battery Pack Chargers

  • An optional external battery pack charger is available for applications that requiring extended or extremely long runtimes (4 or more external battery packs)
  • These chargers can shorten the recharge time of all the connected battery packs exponentially
  • Critical for installation environments that experience frequent outages or long periodic outages
Battery Technology

  • All Endeavor 5-10kVA units and battery packs use valve-regulated lead-acid batteries (VRLA); safe for all freight transport
  • For added protection, all models ship with batteries disconnected.
  • A Quick Installation Guide is included with each unit to detail how to connect the batteries before startup

Hot-Swappable Batteries

  • Batteries in the Endeavor Series UPS can be replaced without the need to shut down the unit (requires removal from rack)
  • Connected loads are protected from voltage anomalies and spikes and surges while the batteries are being replaced.

WARNING: This product can expose you to chemicals, including Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to: www.P65warnings.ca.gov/product

Software

Get ultimate control over your power with SentryHD

In today’s complex world of data, networks, and software, control and management of applications is vital, especially when it comes to the power that is supplied to these devices.

SentryHD, included free with all current Minuteman UPS systems, is the latest update to Minuteman’s popular Sentry monitoring and management software. This powerful tool provides users and network managers a range of monitoring & managment tools for their power, allowing total control before, during, and after power problems.

With a simple connection to the UPS via USB or RS-232, SentryHD provides the capability to configure UPSs, monitor power, and diagnose issues, all from secure connections on the network. This eliminates wasteful runs around the facility, saving time and money.

Accessories

Extended Runtime Capability

  • All models come bundled with a battery pack module
  • For protection through extended blackouts, the Endeavor Series can also utilize connections built into each battery pack to connect multiple units, providing virtually unlimited runtime capabilities

 

Battery Pack Models

Because each UPS has different battery requirements to support its maximum load capacity, the Endeavor 5-10kVA Series uses battery packs sized to match each UPS model.

 

External Battery Pack Chargers

  • ED-BP192CHARGER – charger for BP192RTXL (5 & 6kVA)
  • ED-BP240CHARGER – charger for BP192RTXL (8 & 10kVA)
  • An optional external battery pack charger is available for applications that requiring extended or extremely long runtimes (5 or more external battery packs)
  • These chargers can shorten the recharge time of all the connected battery packs exponentially
  • Critical for installation environments that experience frequent outages or long periodic outages

 


Power Management via SNMP Communication

Optional SNMP-NV6 and SNMP-NET cards allow easy management of UPS without the need of a connected PC or server

  • SNMP-NV6
  • SNMP-NET

Optional Programmable Relay Card:

  • Monitors UPS events
  • 6 programmable relay output contacts
  • Configurable normal open or normal close for each relay contact
  • Configurable UPS shutdown delay time
  • Configurable input signal as shutdown UPS or battery test
  • Has the ability to protect up to 6 computers unattended shutdown gracefully

WARNING: This product can expose you to chemicals, including Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to: www.P65warnings.ca.gov/product

Extended Warranty Plan

5 Full Years of Trouble-free Service – Guaranteed

Minuteman UPSs already ship with the best warranty in the business at 3 years, including non-prorated battery coverage on most products.

Two levels of Extended Warranty Plans are also available on most UPS product lines to provide an additional 2 years of coverage. These plans ensure a full 5 years of trouble-free ownership.

For complete product information, brochures and manuals visit out Media Resources Center.

Product Specification Links

ED5000RTXL | ED5200RTXL          ED6000RTXL | ED6200RTXL
ED8000RTXL | ED8200RTXL          ED10000RTXL | ED10200RTXL

MODELS

Model - 208/240V Output Only (120V Capable)ED5200RTXL (ED5000RTXL)ED6200RTXL (ED6000RTXL)ED8200RTXL (ED8000RTXL)ED10200RTXL (ED10000RTXL)
Maximum Power Capacity5000VA / 4500W (4556VA / 4100W)6000VA / 5400W (5556VA / 5000W)8000VA / 7200W (6889VA / 6200W)10000VA / 9000W (8889VA / 8000W)

TopologyDouble Conversion Online, True Sine Wave

Input Plug TypeHardwire Only (Hardwire / L6-30P/pigtail cord included)Hardwire Only (Hardwire Only)
Output Outlet Type(6 - NEMA 5-15/20R, 1 - L6-20R, 1-L6-30R)Hardwire Only (8 - NEMA 5-15/20R, 1 - L6-20R, 1 - L6-30R)

Input
Single (1Φ 2W + G)
Nominal Voltage208VAC
Acceptable Input Voltage 0 - 300VAC

Voltage Range156 - 280VAC180 - 280VAC

Power Factor Correction=99% at Full Load
Frequency Limits 40 to 70Hz at Full Load
Low Voltage Transfer Point156/180 resets to Utility Power at 166/190VAC or higher
High Voltage Transfer Point280VAC resets to Utility Power at 270VAC or lower
Input ProtectionResettable Circuit Breaker

Output: Online
Voltage Range208VAC: 204 - 212VAC
Voltage RegulationNominal +/-2%
Frequency Range50/60Hz, auto sensing, +/-00.1Hz (unless synchronized to utility)
Efficiency (On-Line Mode) >90% (Full Load)

Output: Battery
Waveform TypeTrue Sine Wave
Nominal VoltageDefault: 208VAC, User-selectable:220/230/240VAC
Voltage RegulationNominal +/-2% (until Low Battery warning)
Frequency50/60Hz, +/-0.1Hz
Votlage T.H.D.=2% (Linear Load)
Dynamic Response+/-5% @ 100% Load change in 30ms
Transfer Time0 ms
Slew Rate=1Hz / second

Crest Factor3 : 12.7 : 1

Overload Capacity=106% - =110% for 10 minutes / =111% - =125% for 5 minutes / =126% - =150% for 30 seconds

Battery
System Voltage192VDC240VDC

Runtime: Half Load (minutes) 12111412
Runtime: Full Load (minutes) 4354

Surge Protection
Surge Energy Rating1050J
Surge Current Capability 6500 Amps total
Surge Response Time1.2µs normal mode; <50µs common mode
Surge voltage let-through (as a percentage of an applied ANSI C62.41 Cat. B +/-4kV) <10%
Noise Filternormal and common mode EMI/RFI suppression
Audible Noise at 1m (3 ft.) <60dBA

Environmental
Operating Temperature (max) 0 to +40°C (+32 to +104°F)
Storage Temperature -15 to +50°C (+5 to +122°F)
Operating/Storage Humidity 0 ~ 95% Non-Condensing
Operating Elevation0 to 2,000m (0 to +6,562 ft.)
Storage Elevation0 to 15,000m (0 to +49,213 ft.)

Surge Protection and Filtering
Surge Energy Rating (Joules) 140J254J

Surge Protection
Safety and ApprovalscTUVus (Conforms to UL1778 4th Edition & CSA 22.2 no. 107.3-05), RoHS 2 Certified
EMC VerificationFCC Class B, CE Certified
Warranty - Platinum ProtectionThree-years parts, labor, and battery (non-prorated); 5-year extended plans available - $200,000

EXPLORE RESOURCES